Home > Products > Electrical Transformer > Power Transformer > 4 Mva 3 Phase Transformer In Power System
4 Mva 3 Phase Transformer In Power System
  • 4 Mva 3 Phase Transformer In Power System4 Mva 3 Phase Transformer In Power System
  • 4 Mva 3 Phase Transformer In Power System4 Mva 3 Phase Transformer In Power System

4 Mva 3 Phase Transformer In Power System

As an expert manufacture of power transformer, Conso Electrical Technology and Science Co., Ltd has the ability to produce 4 Mva 3 Phase Transformer In Power System in power system. To fit the Power demand of chemistry plant steel company and mining company, Conso Electrical equipped production machine to have the ability to manufacture the large capacity power and distribution transformers, such as a 10/0.4 kV 4 mva 3 phase transformer. Evermore, Conso Electrical build a stable partnership with various client group. It not only limit to the State Grid Corporation of China, but also the terminal users such as manufacturing enterprise, wharf, and shopping mall.

Send Inquiry

Product Description

Video



4 mva 3 phase transformer in power system Installation specifications:


1.When pushing the transformer from the wide side, the low-voltage side should face outward. When pushing it from the side, the oil-side should be outward for easy live inspection.

2.Safety distances in the transformer room: For indoor transformers, the distance from the door should not be less than 1 meter, and from the wall, it should not be less than 0.8 meters. For transformers with a rated voltage of 35KV and above, the distance from the door should not be less than 2 meters, and from the wall, it should not be less than 1.5 meters. The brackets for secondary lines of the transformer should be at least 2.3 meters above the ground, and protective barriers should be added on both sides of high-voltage lines. In cases where the transformer room has operational switches, there should be an operational width of at least 1.2 meters in the direction of operation.

3.The transformer room is considered a Class I or Class II fire-resistant building, and the materials used for its main door and intake/exhaust windows should meet fire safety requirements.

4.Iron doors should be used in the transformer room, and if wooden doors are used, they should be clad with galvanized cold-rolled steel sheets (commonly known as iron sheets). The door's width and height should be determined based on equipment installation, typically around 1.5 meters in width and 2.5-2.8 meters in height, and the door should open outward. For smaller distribution rooms (less than 7 meters), one exit is allowed, but for those exceeding 7 meters, there should be no less than two exits.

5.The height of the transformer room's ceiling should meet the design requirements, generally not less than 4.5-5 meters.

6.Inlet and outlet louvers should have an inner layer with mesh openings not exceeding 10mm x 10mm to prevent the entry of animals. For ground-level inlet openings, louvers are not required, but vertical iron bars should be installed outside the mesh to prevent mechanical damage to the mesh. The vertical iron bars can be made from 1mm diameter round steel with 100mm spacing.

7.The top of exhaust windows in the transformer room should be close to the beams. The temperature during natural ventilation should not exceed 45°C. The effective area of the outlet should be 1.1-1.2 times greater than the effective area of the air inlet.

8.When the temperature of the incoming air for natural ventilation is 30°C, the distance from the transformer room floor to the outdoor floor should be 0.8 meters. When the incoming air temperature is 35°C, the distance should be 1 meter.

9.There should be no non-electrical pipelines passing through the transformer room. Measures should be taken to prevent small animals from entering cable conduits.

10.When the oil quantity of a single transformer exceeds 600 kg, an oil pit should be provided.

 

4 mva 3 phase transformer in power system Technical Parameter:


Rated Capacity:  4 mva;
Mode:  S13-M-4000 or depends;
Voltage Ratio:  11/0.415 kV, 22/0.433 kV, 35/0.4 kV;
No loading loss:  as the requirement of client or IEC 60076 ;
loading loss:  as the requirement of client or IEC 60076 ;
Impedance:  5.5% ± 10%;
Short Circuit Current: ≤0.4%;
Vector Group:  Dyn11, Yd11;
Temperature Rise(oil top/winding average): 6 0K/65K or depends;


CONSO·CN 4 mva 3 phase transformer in power system Detail:


Transformer Winding:



Transformer in Application:



CONSO·CN 4 mva 3 phase transformer in power system Workshop:


Winding Workshop

Coil Drying Area

Oil Filling Area

Finished Product Area


4 mva 3 phase transformer in power system Testing Center:



4 mva 3 phase transformer in power system Producing Equipment:


Transformer Oven

Casting Equipment

Foil winding machine


CONSO·CN 4 mva 3 phase transformer in power system Ready to Ship:



Package method:


Wooden Box

Steel Structure



Hot Tags: 4 Mva 3 Phase Transformer In Power System, China, Manufacturers, Factory, Suppliers, Price, Cost

Related Category

Send Inquiry

Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept